请使用支持JavaScript的浏览器!
主营:临床检验
℡ 4000-520-616
℡ 4000-520-616
Pointescientific/Pointe 180 II/90.P3304-180/1 Ea
产品编号:90.P3304-180
市  场 价:¥0.00
场      地:美国(厂家直采)
产品分类: 仪器类>其它类仪器>其他>
联系QQ:1570468124
电话号码:4000-520-616
邮      箱: info@ebiomall.com
美  元  价:待定
品      牌: Pointe
公      司:Pointe Scientific, Inc
公司分类:
Pointescientific/Pointe 180 II/90.P3304-180/1 Ea
商品介绍

Pointe180II

Catalog#:90.P3304-180


GENERALINFORMATION

ThePointe180IIisasmallbenchtopanalyzerdesignedtoreadandcalculatetheresultsofin-vitroclinicaldiagnosticassaysonhumanserum,plasma,orurineaswellasanyotherapplicationrequiringabsorbanceorconcentrationreADIngs.Theanalyzerisprovidedwith43pre-programmedtestparametersandiscapableofstoringupto120assaysinmemoryforlaterrecall.Theanalyzerisequippedwithabuiltinvacuumpumpandexternalwastebottlewithlevelsensing.Theanalyzerissuppliedwitharemovableflowcelltoallowforuseof1cmsquareaswellas12mmroundcuvettes.Theanalyzerisdesignedwithmanyfeaturestominimizeoperatorerror,suchasstablefactorycalibration,pre-programmedcalculations,visualandaudIBLefeedback,flagsanderrormessages.Inaddition,itwillstoreupto512patientresults,512controlresults,20patientsonaworklistand15testsperpatient.*

*Notavailableforclinicalhumanbloodtestinginthe US

ORDERING INFORMATION

Catalog#:

Product:

90.P3304-180

Pointe180II

 

FEATURES

BichromaticPhotometer:
Differentialwavelengthstocorrectimperfectionsintesttubesorsquarecuvettesandtohelpremoveinterferingsubstances.Sixstandardfilterswithtwooptionalfilters(340-700nm)

Temperaturecontrolledcuvette:
Constant37°Ccuvetteandcuvettewellwhenoptionaltubeorsquarecuvettesmodesareused.

InternalTemperaturecontrol:
Theanalyzermonitorstheincubatorandcuvettetemperatures.Thetemperaturesareautomaticallycorrectedandtheactualtemperatureindegrees(C)isdisplayedonthescreen.

LampSaverFeature:
Theinstrumentautomaticallyshutsoffthelampiftheinstrumenthasnotbeenusedfor15minutes.Thisfeaturecanpreservethelampforuptotwoyears,dependingontheactualusage.

QCTrackingFeature:
TheinstrumentsoftwarecanstorecontrolvaluesandcreateLevy-Jenningsplots.

WorklistandPatientreports:
Theinstrumentcancreate,storedandprintworklistandpatientreportstoon-boardthermalprintertoexternalprinterandPC.

DifferentCuvettemodes:
Theanalyzerflowcellisremovabletoallowuseofround12mmglasstubeor1cmsquarecuvettes.

Flip-updisplay:
Large240x128pixelgraphicaldisplay.

PreprogrammedChemistryProcedures:
OptimizedparametersforPointeScientificreagentsarepreprogrammed.120openchannels.

KineticPlots:
Showskineticplotsinrealtime.

MaintenanceFree:
Theanalyzerdoesnotrequireanyscheduledmaintenanceprocedures.

 

SPECIFICATIONS

SpectrophotometerType:

Filter

OpticalConfiguration:

Singlebeamwithcontinuouslyrotatingfilterwheel.Monochromaticorbichromaticreading8filterpositions.

UsableSpectralRange:

330to770nm

SystemProcedures:

OpenandStoredMenu.

CalculatingModes:

-Absorbance

 

-SingleStandard 

 

 DifferentialSamples

 

-FactorMode 

 

DifferentialSamples 

 

-Multi-StandardMode (upto7standards)

 

 DifferentialSamples

 

-Multi-Standard% ABS(upto7standards) 

 

DifferentialSamples 

 

-KineticMode(Consecutively,orSimultaneously(Batch)) 

 

ByFactororStandard 

 

-FixedTimeKinetic 

 

ByFactororStandard 

 

-IndexMode 

Channels:

120open

SourceofRadiation:

TungstenHalogen,10watt,withautomaticlampsaver.

SelectionifWavelength:

ByFilter.

FilterType:

4-cavityinterference,long-lifeionbeam-assisteddeposition.

WavelengthAccuracy:

±3nm

FilterLocation:

Aftersample(heatabsorbingfilterbeforesample).

FilterSelection:

Automaticbysoftwareorviakeyboard.

Wavelengths:

340,405,505,545,580,630,nmsuppliedstandard,othersoptional.

HalfBandwidth:

 

1/100bandwidth:

14nmat340nm.

FalseRadiantEnergyRatio:

<0.001at340and405nm.

Cuvette:

1cmsquare,12mmround,flowthrough.

TypeSupplied:

Flowthrough.

Material:

316stainless,borosilicatewindows.

Geometry:

Cylindrical,2.3mmdiax5mm+/-0.05mm.

IlluminatedVolume:

21ul

MinimumReadVolume:

250ul

Aspiration/Purge:

Vacuumpumpat18cmofHg.

Valve:

Siliconepinchtype

CuvetteHolder:

Thermostaticallycontrolledcompartmentat37°C.

Detector:

Gallium-Arsenide-Phosphidephotodiode.

DisplayType:

240x128graphicLCDw/backlight

Absorbance:

-0.5to3.5(flowthroughmode)
-0.5to2.5(tubeor1cmcuvette)

Concentration:

Maximum999,999

KineticResults:

Abs/minwithresolutionof0.0002A/min

ZeroCompensation:

Automatic

Range:

-0.5to2.5absorbance

Parallel:

Centronics/IBM-PCcompatible

Serial:

RS-232at9600baud,8data,1stop,noparityBi-directional.

DataInput:

1)20keykeypad,2)PS2101keyboard(connectoronback)

SpectrophotometricInaccuracy

 

FlowThrough:

<0.5%at1absorbance,340/630nmNADHSolution.
<1.0%at2absorbance,340/630nmNADHSolution.
<3.0%at3absorbance,340/630nmNADHSolution.
<0.5%at1absorbance,405/630nmPNPSolution.
<1.0%at2absorbance,405/630nmPNPSolution.
<3.0%at 3absorbance,405/630nmPNPSolution.

StABIlity:

Betterthan0.003A/hrmonochromaticafterwarmup.

WarmupTime:

90secondsphotometric,15minutesfortemperaturecompartment.

Electronics:

Z180Microprocessor18MHz,128kEPROM,32KBytesNVRAM.

Power:

Auto-SwitchingPowersupply.
Voltagesource:90-264VAC
Frequency:50/60Hz
Powerconsumption:60watts
InstallationCategory:CATII

 

Fuses:

 

2.5A/250Vfast5-20mmglassfuse

 

2.0A/250VFast5-20mmCeramicFuse 

 

(2)6/10250Vslowblow3AGFuses 

DimensionsandWeight:

40cm(L)x37cm(W)x14cm(H)lidclosed(30cmlidopened),6.4kg

SpaceRequirements:

10cmclearanceonallsides.

EnvironmentalConditions

forSafeOperation:

IndoorUseAltitudeupto2000m.
Temperature5°Cto40°C(Althoughitmaybesafetooperateintheseconditions,itmaynotbesuitablefortheperformanceoftheuser’stests.
Humidity85%fortemperaturesupto30°Cdecreasinglinearityto50%humidityat40°C.
Mainssupplyvoltagefluctuationsnottoexceed+/-10%ofnominalvoltage.

RecommendedOperatingTemperature:

15-35°C

RecommendedOperatingHumidity:

Between10and85%,non-condensing

 

品牌介绍

GENERALINFORMATION

ThePointe180isasmall,semi-automatedchemistryanalyzerwithsixfiltersandalargetestmenu.Ithasanonboardincubatorwith12wellsat37°C,atemperaturecontrolledcuvettewell,andinternaltemperaturecontrol.Theanalyzerleadstheuserthroughtestperformanceinastep-by-stepmanner.Thenewgraphicssoftwareallowsextendedtimedabsorbanceintervaldataandkineticdataplotstobeprinted.

Theanalyzerhas48programmedand21openchannels,andreads,calculates,andprintsresultsinlessthanthreeseconds.Theanalyzerreadstesttubesuponinsertion----noneedtopressabutton.OptimizedparametersforPointeScientificreagentsarealreadyentered-justselectthetestnumber.Openchannelsareavailableforprogrammingothertests.Thenormalrangeforeachtestisautomaticallyprintedout,andresultsthatareoutofthenormalrangeareflagged.Normalrangescanbeeditedtofittheareaorpopulation.ResultsgeneratedbythePointe180arecomparabletoresultsreportedbyhospitalandreferencelabs.

Theanalyzercanusesinglepointcalibrationbystandard/factor,multi-pointcalibrationwithpointtopointcurvefit,percentabsorbanceandratebystandardorfactor.Thesecalculationoptionsallowtheanalyzertoperformendpoint,initialrate,kineticrateandbatchkineticmethodologies.

ORDERING INFORMATION

Catalog#:

Product:

90.P5025-180

Pointe180

 

RELATEDPRODUCTS

Catalog#:

Product:

90-12B-01

12x75mmtesttubes

90-P1907-03

PrinterPaper

 

FEATURES

BICHROMATICPHOTOMETERSYSTEM:
Differentialwavelengthstocorrectfortesttubeimperfectionsandtohelpremoveinterferingsubstances.

ON-BOARDINCUBATOR:
12wellsat37°C.

TEMPERATURECONTROLLEDCUVETTEWELL:
Constant37°C.Thisfeatureisnecessaryforperformingkineticassays.

INTERNALTEMPERATURECONTROL:
Theanalyzermonitorstheincubatorandcuvettewelltemperatures.Thetemperaturesareautomaticallycorrectedandtheactualtemperatureindegrees(°C)isdisplayedonthescreen.

LAMPSAVINGFEATURE:
Theinstrumentautomaticallyshutsoffthelampiftheinstrumenthasnotbeenusedfor15minutes.Thisfeaturecanpreservethelampforuptotwo(2)years,dependingonactualusage.

MAINTENANCEFREE:
Theinstrumentdoesnotrequireanyscheduledmaintenanceprocedures.

SELF-PROMPTINGOPERATION:
Theanalyzerleadstheuserthroughtestperformanceinastep-by-stepmanner.

TESTTUBEACTIVATEDREADING:
Theanalyzerreadstesttubesuponinsertion-noneedtopressabutton.

FASTREADOUT:
Theanalyzerreads,calculatesandprintsresultsinunderthree(3)seconds.

PREPROGRAMMEDCHEMISTRYPROCEDURES:
OptimizedparametersforPointeScientificreagentsarealreadyentered-justselectthetestnumber.Openchannelsareavailableforprogrammingothertests.

PREPROGRAMMEDDATAREDUCTION:
Calculationprogramsforcardiacriskfactors,glycohemoglobinandIron/TIBCarepartofthegeneraltestmenu.

PREPROGRAMMEDNORMALRANGES:
Theanalyzerprintsthenormalrangesandcanbeeditedtofittheareaorpopulation.

PREPROGRAMMEDFLAGS:
Theanalyzerwillflagresultsthatareoutofthenormalrangeorexceedthelinearlimitsoftheanalyzerorreagents.

AUTOMATICWAVELENGTHSELECTOR:
Theanalyzerautomaticallypositionsthepreselectedfiltersforeachtest:340,405,550,600nm.Theinclusionofthe340nmfilterenablestheanalyzertoperformassaysintheultra-violet(UV)mode,whichisthepreferredmodeforenzyme/kinetic,assays.

VARIETYOFCALCULATIONOPTIONS:
Theanalyzercanusesinglepointcalibrationbystandard/factor,multi-pointcalibrationwithpointtopointcurvefit,percentabsorbanceandratebystandardorfactor.Thesecalculationoptionsallowtheanalyzertoperformendpoint,initialrate,kineticrate,andbatchkineticmethodologies.

EIAPROCEDURES:
ThePointe180iscapableofperformingenzymeimmunoassayproceduressuchasTheophylline,TSH,TU,T4andothersbasedonitscurvefittingcalculationcapABIlity.

GLYCOHEMOGLOBINANALYZER:
Readsandcalculatesresultsautomaticallyin%glycohemoglobin.

CARDIACRISKANALYZER:
Automaticallycalculates%HDL,LDL/HDLratio,andassignsariskfactorusingdirectmeasurementsofHDL,LDL,andCholesterol.TheCardiacRiskAssessmentisbasedoneitherDirectLDLMeasurementorcalculatedLDL.

ELECTROLYTEANALYZER:
PerformsCO2andChlorideusingchemistrymethodologies.

IRON/TIBCANALYZER:
RunsTotalIronandUnsaturatedIronBindingCapacityandautomaticallycalculatesTotalIronBindingCapacity.

CHEMISTRYANALYZER:
Performsallbasicchemistryproceduresquickly,easilyandeconomically,usingthelatestmethodologies.ResultsgeneratedbythePointe180analyzerarecomparabletoresultsreportedoutbyhospitalandreferencelabs.

GRAPHICCAPABLESOFTWARE:
Newgraphicsoftwareallowsextendedtimedabsorbance,intervaldata,andkineticdataplotstobeprinted.

 

SPECIFICATIONS

LinearMeasurementRange:

0.0to2.50AbsorbanceUnits(A)

PhotometricAccuracy:

±(1%ofthereading+0.005A)at1.5A

                                                                       

±(2%ofthereading+0.005A)at1.5-2A

LightSource:

TungstenHalogenLamp

Wavelengths:

340,405,450,490,550,600nm

TypicalHalfBandpass:

10nm

TypeofFilter:

Multiple-cavitysealedinterference

TubeSize:

12mmroundstandard

MinimumFillVolume:

1mL

MaximumFillVolume:

2mL(fortemperaturecontrolto37°Conly)

Temperature:

37°C(±0.3°),Blockstayson,Cellhason/offswitch

Lampsavertime:

After15minutesidle

Speed:

Reads,calculatesandprintsresultsin3seconds

Display:

Alphanumeric,16character,LCD

Printer:                                                           

Thermal,dotmatrix,20charactersperline

Keyboard:

16key,membraneswitch,4X4,audIBLeresponse

Calculationmodes:

Singlepointcalibrationbystandardorfactor

 

multipointcalibrationwithpointtopointcurvefit

 

multipointpercentabsorbanceratestandardorfactor(batchorsingle)

 

fixedtimekinetic

Fuserequirements:

120VAC-0.6A,3AGsloblo

Power:

Switchselectablepowersupply(115Vor230Vindicated)

 

VoltageSource:110-120/220-240VACfrom50to60Hz

 

InstallationCategory:CATII

 

Powerconsumption:45Watts

 

Fuse:Two0.6A,Trating,250Vsloblo,3AGtypefuses

 

Allpowercordsmustbeapprovedforthecountryofuse

Dimensions:

9.5X13.25X3.75inches(24X34X10cm)

Weight:

Approximately10lbs(4.5Kg)

 

自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔